Weight Impact: The battery will be
clamped on the impact table, impacted
by the 10KG hammer falling from 1M
height. The battery shows no explosion
and no fire.
Thermal exposure: The battery will
be in 150¡À2¡æ temperature condition.
The duration of the test shall be
30 minutes. The battery shows no explosion
and no fire.
Overcharge : Fully charged battery
is charged continuously with the external
power supply of the limit voltage
of 10V and the current of 3C. The
battery should not rupture, smoke,
catch fire, vent or leak.
Overdischarge: The battery shall be
subjected to a discharge at a constant
current of 0.2C and the test shall
be continued 12.5h,even the battery
reaches 0V.The battery shows no explosion
and no fire.
Short-circuit: Fully charged battery
is to be short-circuited by connecting
the positive and negative terminals
with a tatal resistance of less than
50m¦¸. The battery shows no explosion,
no fire and the exterior temperature
of the cell shall not exceed 150¡æ.
Crush£º The battery shall be crushed
using a crushing force of 1140N. The
battery shows no explosion and no
fire.
Free fall: The battery shall be dropped
from 1m onto a hard wood floor in
different position. The battery shows
no venting, no explosion and no fire.
|